The importance of supervised monitoring modules used in control and monitoring of extinguishing systems

In many places from chemistry laboratories to industrial facilities, in order to ensure the safety of life and property in opposition to a potential fire hazard, extinguishing methods are used in addition to detection and alarm systems. It can also be extraordinarily necessary that the extinguishing methods put in could be triggered by the hearth extinguishing management panel, in order to eliminate a possible hearth with early intervention.
In order to meet these wants, and with 35 years of sectoral knowledge and experience, Mavili Elektronik provides:
Maxlogic Conventional Fire Extinguishing Control Panel operating based on the cross-zone detection principle;
Maxlogic Extinguishing Status Indicator Unit, which allows the distant performance of the indications and controls on the Control Panel;
Maxlogic Extinguishing Output Expansion Panel;
Maxlogic Extinguishant Manual Release Button, which allows the extinguishing process to be started manually and remotely; and
to make certain that the extinguishing process may be paused, Maxlogic has produced the Extinguishant Emergency Stop Button.
pressure gauge ราคา are produced using surface-mount expertise and are geared toward making the automation of the extinguishing system and fireplace and gas detection system perfect.
Image copyright: Mavili
Mavili Elektronik develops its products by all the time contemplating the needs of the set up. In circumstances that require the integration of the extinguishing system with the clever addressable fireplace detection system, it supplies options via the monitoring modules that even have a ‘supervised’ choice.
Supervised monitoring modules play an essential position in controlling the continuity of the cable connection between the loop and the extinguishing system. Failure to detect a attainable open or short circuit within the wiring between the contact monitoring modules and the peripheral systems may cause disruption of the triggering, with potentially critical consequences. For this cause, when selecting monitoring modules, it ought to be taken under consideration that they’ve supervised options.
Image copyright: Mavili
Since Maxlogic intelligent addressable fire detection and alarm management panels are continually speaking with ‘supervise’ contact monitoring modules connected to cable loops and compliant with EN 54-17 and EN 54-18 standards, it makes it simpler to monitor conditions corresponding to open circuits and short circuits which will occur in the system. Many duties can be performed in the fire extinguishing installation, such because the control and monitoring of all valves that may interrupt the circulate of water, water flow alarm switches, strain switch, and electrical or diesel fire pumps.
By adding two contact monitoring modules to 2 separate relay outputs located above the Maxlogic Conventional Fire Extinguishing Control Panel, one of many modules can be utilized to control errors and the other to manage the hearth scenario, monitoring and control of the extinguishing system through an intelligent addressable fireplace detection and alarm system could be performed effectively.
For more information, go to www.mavili.com.tr/en